HP StorageWorks EVA4400 iSCSI Connectivity Option (mpx100b) 5.0 (5697-0512, June 2010)

Ordered tagged commands
Ordered delivery of iSCSI commands is not guaranteed for applications running on iSCSI initiators
that use ordered tagged commands. HP is investigating a fix for a future release of mpx100b firmware.
Private iSCSI network for mpx100b GbE ports
To ensure adequate performance and data security, HP recommends using a private Gigabit Ethernet
(GbE) network between the iSCSI initiators and the mpx100b in any iSCSI configuration.
The iSCSI technology is low cost and uses standardized network adapters and topology hardware.
However, existing networks must be evaluated for their capacity to support iSCSI storage.
Workaround
If you are not using dedicated switches, consider using separate virtual LANs (VLANs).
Resolving an IP conflict on an mpx100b if the IP port does not clear the LED indication on the
mpx100b
When the mpx100b recognizes an IP conflict with its management ports, its fault LED blinks four times,
once per second, and then off for two seconds. The following error message is displayed:
checkDuplicateIp: Detected Error MAC address
The management port is still enabled and uses its IP address.
Workaround
To clear the LED, turn the mpx100b beacon light off using either the mpx Manager or the CLI beacon
off command.
Supersedes history
This version supersedes firmware version 2.4.4.0.
Effective date
June 2010
EVA4400 iSCSI Connectivity Option (mpx100b) 5.0 13