HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 CLI Reference Guide (TB581-96335, April 2013)

Format for XP24000/XP20000
When the command is used to expand a THP pool:
hdvmcli [URL] ModifyPool [options]
model=model serialnum=serial-number poolid=pool-ID
adddevnums=device-number-of-logical-unit
[threshold=THP-pool-threshold-1]
[overprovisioningwarning=over-provisioning-warning-threshold]
[overprovisioninglimit=over-provisioning-limit-threshold]
When changing the thresholds only:
hdvmcli [URL] ModifyPool [options]
model=model serialnum=serial-number poolid=pool-ID
[threshold=THP-pool-threshold-1]
[overprovisioningwarning=over-provisioning-warning-threshold]
[overprovisioninglimit=over-provisioning-limit-threshold]
Parameters
Table 74 ModifyPool command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
Pool ID
Specify the pool ID of the THP/Smart pool that you plan to expand
or whose settings you plan to change.
Required
poolid
Threshold1 of the THP/Smart pool (%)
The threshold1 of the THP/Smart pool is the usage rate of the
THP/Smart pool.
The following values can be specified when modifying the
threshold value:
For P9500 whose microcode version is earlier than 70-01-
4X-XX/XX:
Specify a multiple of 5 in the range from 5 to 95.
For P9500 whose microcode version is 70-01-4X-XX/XX or later:
Specify an integer in the range from 1 to 100.
For XP24000/XP20000:
Specify a multiple of 5 from 5 to 95.
You need to specify a value smaller than the one specified for
threshold2.
Optional
threshold
#1, #2
CLI Reference Guide 207