HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 CLI Reference Guide (TB581-96335, April 2013)

hdvmcli [URL] ModifyVirtualVolume [options]
model=model serialnum=serial-number assign=false
devnums=device-number-of-THP-volume
When the command is used to change the usage rate threshold of THP volumes:
hdvmcli [URL] ModifyVirtualVolume [options]
model=model serialnum=serial-number
devnums=device-number-of-THP-volume
threshold=usage-rate-threshold-of-THP-volumes
Parameters
Table 79 ModifyVirtualVolume command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
Specify true to assign THP volumes to a THP pool.
Specify false to release THP volumes from a THP pool.
Omit this parameter if you are changing the threshold value.
Optional
(XP24000/XP20000)
assign
Device number(s) of THP/Smart volume(s)
Specify this parameter as a decimal number or colon-delimited
hexadecimal number in the format ww:xx:yy, where ww is the
LDKC number, xx is the CU number, and yy is the LDEV number.
ww is optional. If ww is omitted, LDKC is assumed to be 0.
Use a comma to delimit multiple values.
Required
devnums
Pool ID of the THP pool
You need specify this parameter only if true is specified for the
assign parameter.
Optional
(XP24000/XP20000)
poolid
Usage rate threshold for the THP volumes (%)
Specify this parameter when you are assigning THP volumes to
a THP pool, or when you are changing the threshold value.
Specify a multiple of 5 from 5 to 300.
If this parameter is omitted when true is specified for the assign
parameter, 5 is set.
This parameter must be specified if the assign parameter is
omitted.
Do not specify this parameter when false is specified for the
assign parameter. If the parameter is specified in this condition,
an error will occur.
Optional
(XP24000/XP20000)
threshold
Capacity of the THP/Smart volume after expansion (KB)
Specify the capacity of the expanded volume. The maximum value
that can be specified is 64424505600.
Optional
(P9500)
capacity
CLI Reference Guide 229