HP StorageWorks P9000 Replication Manager Software 7.1.1 Configuration Guide (TB584-96029, September 2011)

List of 1 WWN elements:
An instance of WWN
WWN=50.00.08.70.00.30.55.04
3. If the execution results and the values specified in the RAID Manager configuration definition file
do not match, execute the AddStorageArray command to refresh the storage system information.
AddStorageArray ipaddress=IP-address family=array-family
Specify the storage system IP address for IP-address. For XP24000/XP20000, you can use an
IPv6 address. Specify the arrayFamily value, which is acquired by the GetServerInfo
command, for array-family. For details about how to execute the GetServerInfo command,
see Acquiring a list of array families on page 132.
The example below shows how to refresh information about a storage system whose array family
and IP address are assumed to be XP1024/128 and 10.208.115.127, respectively.
hdvmcli AddStorageArray ipaddress=10.208.115.127 family=XP1024/128
An example of the command execution results is shown below. In this example, you can see that
the information about the storage system, whose arrayFamily value is XP1024/128 and
whose ipAddress value is 10.208.115.127, has been refreshed.
RESPONSE:
An instance of StorageArray
objectID=ARRAY.D800S.83000101
name=D800S@10.208.115.127
description=D800S (83000101) at 10.208.115.127
:
numberOfImReservedLUs=0
List of 1 CommParameters elements:
An instance of CommParameters
userID=CVXPAE
ipAddress=10.208.115.127
ipAddress2=
Checking the pair management server information managed by Device Manager server (for the Core
CLI License)
142