HP XP7 Smart Manager for Mainframe User Guide (TK916-96001, May 2014)

Tiering Policy Group Name : TPG1
Monitor Interval Time(sec): 600
Volume I/O statistics
-------------------------------------------------------
11:23:00 - 11:33:00
-------------------------------------------------------
DEVN,Volser,STORGRP,SN ,CU,CCA,Tier1 IOPS,Tier2 IOPS,Tier3 IOPS
1101,VOL001,SG1 ,14001,00, 01, 100, 253, 1486
1201,VOL002,SG1 ,14001,00, 01, 20, 0, 0
-------------------------------------------------------
11:33:00 - 11:43:00
-------------------------------------------------------
DEVN,Volser,STORGRP,SN ,CU,CCA,Tier1 IOPS,Tier2 IOPS,Tier3 IOPS
1101,VOL001,SG1 ,14001,00, 01, 60, 0, 0
1201,VOL002,SG1 ,14001,00, 01, 4, 0, 0
:
Related topics
KTLOAD, page 150
KTQSTATS, page 158
KTDEMO14 (Check I/O performance information), page 270
About changing tiering policy groups when using the CLI
commands
This section describes how to change tiering policy groups by using CLI commands.
Changing a tiering policy when using the CLI commands
If you need to change a tiering policy due to lowered I/O performance or a change in the purpose
for which volumes are being used, modify the created tiering policy information CSV file, update the
definition, and then apply the update to the storage system.
Procedure
1. Change the tiering policy information CSV file.
2. Execute the KTIMPORT command.
The definition of the tiering policy group is updated with the contents of the modified tiering
policy information CSV file.
3. Execute the KTLOAD command.
The contents of the configuration files are loaded into REXX variable structures.
4. Execute the KTACTTPG command.
Information about the modified tiering policy is applied to the storage system.
5. Execute the KTQRYTPG command to check the tiering policy.
Confirm that the tiering policy has been applied to the storage system.
User Guide 103