HP P9000 Command View Advanced Edition Software Update 7.2.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Version 7.2.0-00 Description This package is a new release of the HP P9000 Command View Advanced Edition Software. For details, see “Enhancements” (page 3). For previous behaviors resolved in this release, see “Fixes” (page 4). Update recommendation Routine NOTE: Installing the Device Manager 7.1.1-01 installs Tiered Storage Manager 7.1.1-01 automatically. Installing the Tiered Storage Manager 7.1.1-01 Service Pack requires installing the Device Manager 7.1.1-01 Service Pack separately.
• The virtualization server product VMware ESXi 5.0 is now supported in the Device Manager server and Device Manager agent. For details on guest operation systems, see the HP P9000 Command View Advanced Edition Suite Software System Requirements.
• If the CLI version did not match the Device Manager server version, the GetPoolShrinkStatus command failed with the KAIC90083-E error. • From the Allocate Volumes dialog box in the GUI, when volumes were manually selected, the Creating volume settings might be displayed incorrectly.
Searching resources Parity group search: Parity groups which can be searched using Keyword Search are in the following storage systems. • P9500 • XP24000/XP20000 • XP12000/XP10000/200 SVS Parity groups in storage systems other than the above cannot be searched using Keyword Search. Volume search: Search results might not be correct if is not is specified as a conditional equation in volume search by label. Only volumes assigned labels can be searched.
Creating XP Snapshot and Business Copy/Snapshot When XP Snapshot and Business Copy/Snapshot are created by using the CLI, the same volume cannot be used by XP Snapshot and Business Copy/Snapshot. Changing status of copy pair by CLI Do not specify the copytracksize parameter when the CLI ModifyReplication command is executed and the status of XP Snapshot is changed.
Installing Host Data Collector • Although prohibited special characters other than semicolon (such as @) can be specified in the installation path, Host Data Collector will not work properly. When you specify an installation path, use the following characters: A -Z, a-z, 0-9, left parenthesis [ ( ], right parenthesis [ ) ], single-byte space, backslash(\).
Setting up resource groups While creating or editing resource groups, do not make configuration changes on resources that are to be added to or deleted from the resource groups. The number of client windows that can be used at one time The maximum number of clients that can connect to Device Manager at one time is seven. If eight or more clients connect to Device Manager at one time, they might be forcibly logged out. If this occurs, wait a few minutes, and then log in again.
1. 2. 3. 4. Navigate to Start→Settings→Control Panel. Double-click Add or Remove Programs. In the Add or Remove Programs window, select Command view Advanced Edition. Click Remove. For details on how to remove Command View Advanced Edition Suite, see the HP StorageWorks P9000 Command View Advanced Edition Suite Software Administrator Guide. 3. Install Command View Advanced Edition.
◦ Adding resources to a resource group ◦ Removing resources from a resource group To add or remove resources, specify no more than 16,000 resources for each resource type. • When multiple resource groups are simultaneously deleted, communication with the Device Manager server might not succeed. Make sure that no more than 16,000 resources for each resource type are assigned to each resource group to be deleted.
When you run the target host log gathering tool (TLC), the file zpool_history_-<1– to 6–digit number>.rst and the file -<1– to 6–digit number>.rst (size: about 250 + 50*disk number that consists pool byte) might be created in the same directory where you ran the TLC tool. Delete these files from the directory after registering hosts, updating host information, or running TLC.
Upgrading Host Data Collector Upgrading resets the port number used by Host Data Collector to the default (23051). Displaying of Host Data Collector When using host discovery with Host Data Collector, the following information cannot be displayed correctly: • IPv6 address in Windows 2008 German Edition. • IPv6 address in Solaris and HP-UX environments if IPv4 address specified by a user for registering host is an alias IP address.
2 Under the SSL configuration for Device Manager Server HiKeytool menu, the operation in submenu 14. Logical groups list When multiple filter conditions are specified for the logical groups list, only the first condition is effective. If multiple filter conditions are required, repeat filtering one at a time, cumulatively. Sorting and filtering The sort order of the following columns might not be correct.
• Drive Type • Drive Speed • No. of Parity Groups • Total Capacity File servers columns: • Model Storage systems columns: • Model Data collection tasks columns: • Target Type The filtering result of the following columns might not be correct. Volumes columns: • No.
Filtering by capacity Do not use the = (equal) operator to filter by capacity. Use the > (greater than), < (less than), >= (greater than or equal to), or >= (less than or equal to) operators to filter by capacity. Sorting multiple columns If multiple columns are sorted, the , , or error might occur. If this occurs, reopen the screen and reduce the number of columns to be sorted.
Allocate Volumes The task registration operation might not continue when a restricted character ('\', '/', ':', ',', ';', '*', '?', '"', '<', '>', '|', ''', ) used for the host group name is displayed by default in the Allocate Volumes dialog box. Change the host group name displayed by default to a name that does not contain one of the characters. The Allocate Volume dialog box might complete successfully if the host is deleted from another browser. As a result, volumes are not allocated to the host.
About Mozilla 1.7.13 (HP-UX 11i v3) If the Device Manager GUI uses Mozilla 1.7.13 on HP-UX 11i v3 for PA-RISC, the IPv6 protocol cannot be used to communicate with the Device Manager server. Using the CLI to create copy pairs If the replicationfunction parameter is omitted in either of the following operations, a KAIC90083-E error occurs.
Using the GUI with Windows Server 2003 and Windows Server 2008 Because Internet Explorer on Windows Server 2003 and Windows Server 2008 enables Internet Explorer Enhanced Security Configuration (IE ESC) by default, you might experience the following situations: • Loading animation does not move. • You cannot download files from a server with HTTPS enabled. If this occurs, disable the Configure IE ESC.
The number of resources that can be managed by Plug-in for Virtualization Server Provisioning The number of resources that can be managed by Plug-in for Virtualization Server Provisioning is based on the number of resources that can be managed by Device Manager. Use a configuration whose number of resources does not exceed the number that Device Manager can manage. Script error in Plug-in for Virtualization Server Provisioning If Flash Player 10.1 or 10.2 is used, a script error might occur.
A - Z, a - z, 0 - 9, !, #, $, %, &, ', (, ), +, -, ., =, @, [, ], ^, _, {, }, or ~.
• 143(imap2) • 179(bgp) • 389(ldap) • 465(smtp+ssl) • 512(print / exec) • 513(login) • 514(shell) • 515(printer) • 526(tempo) • 530(courier) • 531(chat) • 532(netnews) • 540(uucp) • 556(remotefs) • 563(nntp+ssl) • 587(smtp) • 601(syslog) • 636(ldap+ssl) • 993(ldap+ssl) • 995(pop3+ssl) • 2049(nfs) • 4045(lockd) • 6000(x11) Volumes allocated to ports with LUN security disabled The following notes apply to volumes allocated to ports with LUN security disabled.
The task details dialog box for starting monitoring, stopping monitoring, starting relocation and stopping relocation The KAIC06400-E error of a storage system might be displayed in the message column of the pool selected in the task details dialog box. Check the monitoring status or relocation status of the pool in the pool list. Editing tiering policy The KAIC15017-E error is displayed incorrectly when the tiering policies for reserved THP volumes are edited.
1. 2. Open Command Prompt. Execute the following command: \Host Data Collector\Uninstall_Host Data Collector\Uninstall Host Data Collector.exe If Host Data Collector is upgraded without removing it first, remove Host Data Collector according to the previous procedure, and then install Host Data Collector again.
Allocate Smart Tiers Software volumes To allocate Smart Tiers Software volumes that have been allocated to hosts, perform either of the following operations: • Allocate volumes from the search result window • Allocate volumes from the logical group window KAIC15001-E error message in the GUI If the GUI displays the KAIC15001-E error message, startup of Device Manager might not have completed successfully.
do not install any of these HiRDB products on a computer with Command View Advanced Edition Suite products installed. • HiRDB/Single Server • HiRDB/Parallel Server • HiRDB/Workgroup Server • HiRDB/Run Time • HiRDB/Developer's Kit • HiRDB/SQL Executer Adjusting the computer's time If a computer's time is changed while the services of Common Component and Command View Advanced Edition Suite products are running, Device Manager might not operate correctly.
Automatically generating short file and folder names (Windows) Make sure that the setting for automatically generating short file and folder names (8.3 format) is enabled. Also, when installing, use a Windows account that was created when the setting was enabled. If the above conditions are not satisfied, the install might not be successful, or Command View Advanced Edition Suite might not work properly. Even after installation is complete, do not change the setting for automatically generating short names.
Permissions for the directory Grant all users read and execution permissions to the installation directory, as well as all directories below it. In Linux, the directory specified as the installation directory will have its permissions set to 775. Specify an installation directory for which there will be no issues if the permissions are changed to 775.
Component Manual Device Manager CLI HP P9000 Command View Advanced Edition Suite Software CLI Reference Guide Device Manager agent HP P9000 Command View Advanced Edition Suite Software Administrator Guide Mainframe agent HP P9000 Command View Advanced Edition Suite Software Mainframe Agent Installation and Configuration Guide Compatibility/interoperability None Compatibility/interoperability 29