HP P9000 Command View Advanced Edition Suite Software 7.2 Release Notes

When you run the target host log gathering tool (TLC), the file zpool_history_<zfs pool
name>-<1 to 6digit number>.rst and the file <any character>-<1 to 6digit
number>.rst (size: about 250 + 50*disk number that consists pool byte) might be created in the
same directory where you ran the TLC tool.
Delete these files from the directory after registering hosts, updating host information, or running TLC.
Registering Linux, Solaris, AIX, and HP-UX hosts through Host Data Collector
The error message does not display correctly if the system locale on the target host is set to a
non-English language and the character encoding is not UTF-8.
Registering or refreshing a host of Linux, Solaris, AIX or HP-UX by using Host Data Collector fails
if the PATH environment variable does not contain the following paths:
For Linux: /sbin, /bin, and /usr/bin
For Solaris, AIX, and HP-UX: /usr/sbin and /usr/bin
Registering HP-UX 11iv2 (IPF and PA-RISC) and 11iv3 (PA-RISC) hosts by using Host
Data Collector
Registering or refreshing HP-UX 11iv2 (IPF and PA-RISC) and 11iv3 (PA-RISC) hosts times out if a stale
NFS mount exists on the target host. The following error message occurs when registering hosts of the
same target host:
ERR_1202: Unable to copy all the files to the remote server. (Remote
server: <Target host IP address>, Cause: Error during SCP transfer.)
If this error persists, check whether a Host Data Collector binary process exists on the target host by
executing the following command:
ps -ef |grep /tmp/FsDataGather
If this process exists, delete all processes listed by the command by executing the command kill -9
<process ID> on the target host. Then unmount the stale NFS and execute registering hosts or
refresh hosts again.
Create Volume dialog box
The following message appears if the Create Volume dialog box is opened when all of the parity
groups are reserved:
No parity groups for create volumes. Create a parity group. (KAIC16109-E)
If this occurs, wait until the task using the parity groups ends.
Virtual Parity Group information
Virtual Parity Group information is not displayed in the volume list. Check the Virtual Parity Group
information from the Detailed Information dialog box for each volume.
Overwriting a Host Data Collector installation
When performing an overwrite installation or upgrade installation of Host Data Collector, an
installation message and button label might not be displayed correctly. If Host Data Collector
cannot be installed, uninstall and then reinstall it.
After an overwrite installation, all Host Data Collector properties are set to their default values.
During an overwrite installation of Host Data Collector on Windows, information about the
installation directory and port number are not displayed correctly.
When performing an overwrite installation of Host Data Collector, the system prompts you to
specify a new installation path and port number. Specify the same installation path and port
number used in the previous installation.
12 Important considerations