HP P9000 Command View Advanced Edition Suite Software 7.2 Release Notes

The task details dialog box for starting monitoring, stopping monitoring, starting
relocation and stopping relocation
The KAIC06400-E error of a storage system might be displayed in the message column of the pool
selected in the task details dialog box.
Check the monitoring status or relocation status of the pool in the pool list.
Editing tiering policy
The KAIC15017-E error is displayed incorrectly when the tiering policies for reserved THP volumes
are edited.
If this occurs, check the status of the THP volumes.
Operating the Device Manager GUI
Before completion of drawing a view, do not operate anything for it. If you do so, an unexpected
error such as KAIC16009-E might occur. If this occurs, try the operation again. If this symptom
continuously occurs, log in to the Device Manager again and retry the operation.
View of virtual machine information in Delete Storage window
When a volume is mapped to a virtual machine as a Raw device, information on a virtual machine
mapped the volume might not be displayed in the Delete Storage window of Plug-in for Virtualization
Server Provisioning.
If this occurs, confirm the configuration of the virtual machine with VMware vSphere Client.
KAIC05607-E or KAIC06400-E error during an operation
If the KAIC05607-E or KAIC06400-E error occurs during a Migrate Data operation, some of
the configuration changes might be applied to the storage system. Therefore, the content of the
Task Status displayed in the Migration pairs table on a Task Details dialog of Migrate Data might
not correspond to the configuration of the storage system. If this occurs, refresh the storage system
information and check the current storage system configuration. After that, perform the Migrate
Data operation again using the recent Task Status and the configuration of the storage system.
If the KAIC05607-E or KAIC06400-E error occurs during a Device Manager GUI or CLI operation
to change a storage system configuration, some of the configuration changes might have been
applied to the storage system. Refresh the storage system information and check the current storage
system configuration. After that, continue the configuration change operation by using the Device
Manager GUI, CLI, or Element Manager.
Using Host Data Collector to register Windows hosts on a Solaris or Linux server
If using Host Data Collector on a Solaris or Linux server to register or refresh a Windows host and the
message ERR_1202 is displayed, retry registering or refreshing the host.
ERR_1202 : Unable to copy all the files to the remote server. (Remote
server: <IP_ADDRESS_OF_TARGET_HOST>, Cause: session setup failed: Call
timed out: server did not respond after 20000 milliseconds Receiving SMB:
Server stopped responding)
Upgrading Host Data Collector in Windows
If Host Data Collector is upgraded in a Windows environment in which the path of the environment
variable tmp includes characters other than the following, Host Data Collector does not start:
A-Z a-z 0-9 space ~@#$^&()_+{}`-=[]'.,%!,
In this case, before upgrading Host Data Collector, or if Host Data Collector has already been
upgraded, uninstall it as described, and then install it again:
Important considerations 23