HP P9000 Command View Advanced Edition Suite Software 7.4.0-00 Release Notes (TB581-96329, December 2012)

Filtering in the Logical Group dialog box
When adding volumes in the Logical Group dialog box, you cannot filter by the Encryption column.
If this occurs, filter the volumes with some other criteria first, and then try to sort by the Encryption
column.
Filtering by capacity
Do not use the = (equal) operator to filter by capacity. Use the > (greater than), < (less than), >=
(greater than or equal to), or <= (less than or equal to) operators to filter by capacity.
Warning banner preview
The preview of the warning banner in the setting dialog box does not appear correctly.
Confirm the warning banner in the login dialog box.
Warning banner settings
When you create warning banner messages using the hcmdsbanner command, only the following
HTML tags can be used for warning banners:
<b> </b>
<i> </i>
<center> </center>
<br>
<div dir=”ltr”> </div>
<div dir=”rtl”> </div>
<div style=”direction:ltr”> </div>
<div style=”direction:rtl”> </div>
Creating and allocating volumes
The following items cannot be filtered in the Select THP Pool dialog box:
Used Capacity
Subscription
Allocate Volumes dialog box and Unallocate Volumes dialog box
If a WWN of a host side is changed by another browser when the Allocate Volumes dialog box
appears, an internal error might occur. If this occurs, restart the browser.
The WWN might be changed by another browser when nothing appears in the Plan Summary of the
Unallocate Volumes dialog box. If this occurs, restart the dialog.
Created volumes capacity
When you allocate or create volumes and you do not use whole numbers to specify the capacity, the
volumes might not be created with the specified capacity. If this occurs, delete the created volumes,
and then allocate or create volumes again by specifying the block.
Automatic screen refresh
Even if information displayed on the screen changes during task execution, it might not update
automatically. If this occurs, refresh the screen manually.
30 Important considerations