HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

DescriptionStatusParameter name
Device number of the LDEV that you intend to obtain
Specify this parameter when you want to obtain information about
a specific LDEV. If you specify this parameter, you must also
specify the model and serialnum parameters. If you specify
the model and serialnum parameters, and omit the devnum
parameter, information about LDEVs in the specified storage
system is obtained.
This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200 or XP1024/XP128,
use the xx:yy format, where xx is the CU number, and yy is
the LDEV number. For P9500 or XP24000/XP20000, use the
ww:xx:yy format, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If you omit
ww, the LDKC number is regarded as 0.
The execution results are output in decimal.
Optional
devnum
Information about the LDEV
The value you can specify is VolumeConnection.
Optional
ldevsubinfo
Filter used for selecting the LDEV
Available values are OPEN, INTERMEDIATE, and MAINFRAME,
which are not case-sensitive. To specify two or more values,
separate them with semicolons (;). If you omit this parameter, all
LDEVs are displayed. If you specify OPEN, the LDEVs for an open
volume will be displayed. If you specify INTERMEDIATE, the
LDEVs for an intermediate volume will be displayed. If you specify
MAINFRAME, the LDEVs for a mainframe volume will be displayed.
If you specify OPEN;MAINFRAME, the LDEVs for both the open
volume and mainframe volume will be displayed.
Optional
ldevfilter
Starting sequence number of logical devices for which information
is to be obtained
Specify this parameter when you want to obtain information for
a part of logical devices in a specific storage system.
When logical device information is ordered by device number
(in ascending order) from 0, specify the first number in the
sequence of logical devices that you want to obtain.
This parameter must be specified together with the
numOfElementsFilter, model, and serialnum parameters.
Optional
startElement-
NumFilter
Number of logical devices for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of logical devices in a specific storage system. Specify the
number of logical devices for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Device Manager CLI command reference130