HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

onDemandDevice=false
devType=
isStandardLDEV=true
guardMode=
diskType=0
slprNumber=-1
clprNumber=-1
cacheResidencyMode=-1
stripeSizeInKB=-1
volumeKind=3
status=Normal
thpType=-1
consumedSizeInKB=-1
mfTrueCopyVolumeType=Simplex
mfShadowImageVolumeType=Simplex
mfUniversalReplicatorVolumeType=Simplex
mfUniversalReplicatorPoolID=-1
thpPoolID=-1
threshold=-1
systemDisk=0
encrypted=-1
List of 1 VolumeConnection elements:
An instance of VolumeConnection
objectid=*****
mappedArrayType=XP12000
mappedSerialNumber=10001
mappedDevNum=0
displayMappedDevNum=00:00
externalArrayType=XP12000
externalSerialNumber=10002
externalDevNum=150
displayExternalDevNum=00:96
externalVolumeName=0096
productName=12000
vendor=HP
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=LogicalDKC)
GetStorageArray (subtarget=LogicalDKC) obtains the information about the logical DKC in
one or all storage systems.
Parameters
Table 52 GetStorageArray (subtarget=LogicalDKC) command parameters
DescriptionStatusParameter name
Specify LogicalDKC.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Device Manager CLI command reference132