DescriptionStatusParameter name
Specific information about the logical unit path
The value you can specify is HostInfo or WWN.
If you specify this parameter, you must also specify
lusubinfo=Path.
Optional
pathsubinfo
Information about the LDEV
The value you can specify is VolumeConnection. If you specify
this parameter, you must also specify the lusubinfo=LDEV.
Optional
ldevsubinfo
Filter for selecting a volume for Thin Provisioning Software
Specify either the pool ID of a THP pool, or Unassigned. If you
specify the pool ID of a THP pool, information about the THP
volumes assigned to that THP pool is obtained.
If you specify Unassigned, information about THP volumes not
assigned to a THP pool is obtained.
This information cannot be obtained by the partitioned storage
administrator.
If you specify model and serialnum at the same time, the
specification for this parameter becomes invalid.
Optional
thpvolfilter
Starting sequence number of logical units for which information
is to be obtained
Specify this parameter when you want to obtain information for
a part of logical units in a specific storage system.
When the logical unit information is ordered by device number
(in ascending order) from 0, specify the first number in the
sequence of logical units that you want to obtain.
This parameter must be specified together with the
numOfElementsFilter, model, and serialnum parameters.
Optional
startElement-
NumFilter
Number of logical units for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of logical units in a specific storage system. Specify the
number of logical units for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Device number of the logical unit
Specify this parameter to acquire information about a particular
logical unit. This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200 or XP1024/XP128,
use the xx:yy format, where xx is the CU number and yy is the
LDEV number. For P9500 or XP24000/XP20000, use the
ww:xx:yy format, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If you omit
ww, the LDKC number is regarded as 0.
If you specify this parameter, you must also specify the model
and serialnum parameters.
The execution results are output in decimal.
Optional
displayname