HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

Command execution result 2
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 PortController elements:
An instance of PortController
objectID=*****
cluster=1
card=1
controllerID=1
displayName=CHA-1P
mode=1
type=12
*****: The value is encoded by the CLI.
GetStorageArray (subtarget=ReplicationInfo)
GetStorageArray (subtarget=ReplicationInfo) obtains information about copy pairs.
NOTE:
For XP24000/XP20000 and XP12000/XP10000/SVS200, the partitioned storage administrator
cannot obtain all the information about paired volumes and external volumes.
For XP24000/XP20000, if there is information about copy pairs consisting of mainframe volumes,
microcode version 60-01-6x-xx/xx or later is required. When using an older microcode version
and obtaining copy pair information, the information about copy pairs consisting of mainframe
volumes is output as the information about copy pairs consisting of open volumes.
Parameters
Table 60 GetStorageArray (subtarget=ReplicationInfo) command parameters
DescriptionStatusParameter name
Specify ReplicationInfo.
Required
subtarget
Serial number of the storage system.
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Device Manager CLI command reference160