HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

DescriptionStatusParameter name
Device number used to identify the new path (not provided when
a LUSE is defined)
This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200 or XP1024/XP128,
use the xx:yy format, where xx is the CU number, and yy is
the LDEV number. For P9500 or XP24000/XP20000, use the
ww:xx:yy format, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If you omit
ww, the LDKC number is regarded as 0.
The execution results are output in decimal.
Specify either devnum or lusedevnums. Do not specify both
parameters at the same time. If they are specified at the same
time, an error will occur.
Optional
devnum
Comma-separated list of LDEV numbers to create a LUSE for the
path
The format you can use when specifying and the format of the
execution results are the same as devnum.
Specify either devnum or lusedevnums. Do not specify both
parameters at the same time. If they are specified at the same
time, an error will occur.
Optional
lusedevnums
#
#
The LUSE is created using the LDEVs of the specified device numbers. The new LUSE is created
using only those LDEVs that have the same emulation, sizeInKB, and raidType attributes.
Parameter values to obtain in advance
serialnum and model: Obtain these values from the execution result of the GetStorageArray
command. In the execution result, use the arrayType value or the displayArrayType value to
specify the model parameter, and use the serialNumber value to specify the serialnum parameter.
port, domain or domainnickname, and lun: Obtain these values from the execution result of the
GetStorageArray (subtarget=HostStorageDomain, hsdsubinfo=freelun) command.
Execute this command by specifying only the model and serialnum parameters,
HostStorageDomain for the subtarget parameter, and freelun for the hsdsubinfo parameter.
In the execution result of this command, the portID, domainID and nickname values appear under
An instance of HostStorageDomain. Use these portID values to specify the port parameter.
Use the domainID value to specify the domain parameter, or use the nickname value to specify
the domainnickname parameter.
For the lun parameter, specify one of the lun values that appear under An instance of FreeLUN.
portname: Obtain this value from the execution result of the GetStorageArray (subtarget=Port)
command. In the execution result of this command, the displayName value appears under An
instance of Port. Use this value to specify the portname parameter.
devnum: Obtain this value from the execution result of the GetStorageArray (subtarget=LDEV)
command. Execute this command by specifying only the model and serialnum parameters, and
LDEV for the subtarget parameter. In the execution result of this command, the devNum values of
the LDEVs appear in an LDEV. Use the devNum value of the LDEV for which path=false and
onDemandDevice=false to specify the devnum parameter.
Device Manager CLI command reference202