HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

Parameters
Table 74 AddWWNForHostStorageDomain command parameters
DescriptionStatusParameter name
Serial number of the storage system for the host storage domainRequired
serialnum
Model of the storage system for the host storage domainRequired
model
Port ID of the host storage domain
Specify either port or portname. Do not specify both parameters
at the same time. If they are specified at the same time, an error
will occur.
Optional
port
Port name of the host storage domain
Specify either port or portname. Do not specify both parameters
at the same time. If they are specified at the same time, an error
will occur.
Optional
portname
Domain ID of the host storage domain
This parameter can be specified in decimal and hexadecimal. If
you specify a hexadecimal number, add the 0x prefix.
The execution results are output in decimal.
You must specify either domain or domainnickname. Do not
specify both parameters at the same time. If they are specified at
the same time, an error will occur.
Optional
domain
Nickname of the host storage domain
You must specify either domain or domainnickname. Do not
specify both parameters at the same time. If they are specified at
the same time, an error will occur.
Optional
domainnickname
Comma-separated list of WWNs to secure the host storage domain
If you use the HostScan command to register a host in Device
Manager, every WWN that you specify in the wwn parameter
must be a WWN used by that host only. In this case, the value
specified for the domainnickname parameter is used as the
name of the host. For details about the HostScan command, see
HostScan on page 233.
Required
wwn
Device Manager CLI command reference206