HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

NOTE:
If you do not know the object ID of the required host, you can obtain information about hosts by
executing the GetHost command without specifying this parameter.
Command execution example 1
This example obtains the pair information defined in the RAID Manager configuration definition file
whose configFileID is CONFIGFILE.1.11 in the host whose objectID is HOST.1.
hdvmcli GetHost -o "D:\logs\GetHost.log" "objectid=*****"
configFileID=CONFIGFILE.1.11
*****: The value is encoded by the CLI.
Command execution result 1
RESPONSE:
An instance of Host
objectID=*****
name=toro2
hostID=1
ipAddress=192.168.32.63
capacityInKB=0
hostType=-1
statusOfDBUpdating=0
List of 2 WWN elements:
An instance of WWN
WWN=00.99.66.33.88.55.22.77
nickname=Jane
An instance of WWN
WWN=11.44.77.22.55.88.33.66
nickname=Jone
List of 1 ConfigFile elements:
An instance of ConfigFile
objectID=*****
instanceNumber=11
controlledBy=Device Manager
portNumber=50000
valid=1
List of 1 ReplicationGroup elements:
An instance of ReplicationGroup
objectID=*****
replicationGroupID=3
groupName=HCMD_CG0003
pvolHostID=1
pvolInstanceNumber=11
pvolPortNumber=50,000
pvolHORCMMONHostName=192.168.32.63
pvolHORCMINSTHostName=192.168.32.63
svolHostID=2
svolInstanceNumber=12
svolPortNumber=50,001
Device Manager CLI command reference226