HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

devNum=3
displayDevNum=00:03
osScsiBus=0
osScsiID=15
osLun=1
portWWN=11.22.33.44.55.66.77.88
fileSystemType=NTFS
fileSystemName=C:
sizeInMB=10
percentUsed=10
lastUpdated=1039003852
*****: The value is encoded by the CLI.
Command execution example 2
hdvmcli GetHostInfo -o "D:\logs\GetHostInfo.log"
Command execution result 2
RESPONSE
An instance of HostInfo
objectID=*****
name=HIS_HOSTINFO_XP1024
serialNumber=10001
arrayType=XP1024
ipAddress=172.16.64.159
mountPoint=C:
portID=7
portName=CL1-H
domainID=0
scsiID=15
lun=3
devNum=3
displayDevNum=00:03
osScsiBus=0
osScsiID=15
osLun=1
portWWN=11.22.33.44.55.66.77.88
fileSystemType=NTFS
fileSystemName=C:
sizeInMB=10
percentUsed=10
lastUpdated=1039003852
.
. (repeated for other HostInfo instances)
.
*****: The value is encoded by the CLI.
HostScan
HostScan registers (into the Device Manager server database) any host whose host name is the
nickname of a host storage domain, and adds (to that host's information in the database) the WWN
CLI Reference Guide 233