HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

command, the name value appears under An instance of Host. In the hostname parameter,
specify the name value for the virtualization server whose information you want to refresh.
Command execution example
hdvmcli RefreshVirtualizationServer -o "D:\logs\RefreshVirtualizationServer.log"
"hostname=boss.boss"
Command execution result
RESPONSE:
An instance of Host
objectID=*****
name=boss.boss
hostID=1
capacityInKB=21,995,840
hostType=3
statusOfDBUpdating=0
virtualizationServerVersion=VMware ESX 4.0.0 build-171294
List of 1 CommParameters elements:
An instance of CommParameters
ipAddress=10.208.119.114
portNumber=5989
protocol=Secure
userID=vi-admin
*****: The value is encoded by the CLI.
Server management commands
The Server Management commands provide some management support for the Device Manager
server.
AddURLLink
For Device Manager objects managed by the Device Manager server (referred to as a mainframe
hosts), the AddURLLink command sets information regarding the links to the URLs of the P9000
mainframe agent instances running on mainframe hosts (referred to as URLLinks).
NOTE:
This command does not support virtualization servers.
For details about how to specify the settings for managing mainframe hosts and information on the
AddURLLink command, see Managing mainframe hosts on page 346.
Device Manager CLI command reference244