DescriptionStatusParameter name
Port name in the HORCM configuration file that manages the
P-VOL path.
If you specify this parameter, specify either pvolportid or
pvolportname. Do not specify both parameters at the same
time. If they are specified at the same time, an error will occur.
Optional
pvolportname
Pool ID of the pool in which the differential data and journal data
for the P-VOL is to be stored.
You must specify this parameter when you are using method 2
or 3 with Continuous Access Journal Software, Snapshot Software,
or Continuous Access Asynchronous Software.
For other cases, this parameter value is invalid even if you specify
a value.
Optional
pvolpoolid
Model of the storage system that includes the S-VOLRequired
svolarraytype
Serial number of the storage system that includes the S-VOLRequired
svolserialnum
#
Device number of the S-VOL
This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200, use the xx:yy format,
where xx is the CU number, and yy is the LDEV number. For
P9500 or XP24000/XP20000, use the ww:xx:yy format, where
ww is the LDKC number, xx is the CU number, and yy is the LDEV
number. ww is optional. If you omit ww, the LDKC number is
regarded as 0.
The execution results are output in decimal.
Required
svoldevnum
#
Port number in the HORCM configuration file that manages the
S-VOL path
If you specify this parameter, specify either svolportid or
svolportname. Do not specify both parameters at the same
time. If they are specified at the same time, an error will occur.
Optional
svolportid
Port name in the HORCM configuration file that manages the
S-VOL path
If you specify this parameter, specify either svolportid or
svolportname. Do not specify both parameters at the same
time. If they are specified at the same time, an error will occur.
Optional
svolportname
Pool ID of the pool in which the differential data and journal data
for the S-VOL is to be stored.
You must specify this parameter when you are using method 2
or 3 with Continuous Access Journal Software or Continuous
Access Asynchronous Software.
For other cases, this parameter value is invalid even if you specify
a value.
Optional
svolpoolid
Device Manager CLI command reference254