HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

When using Method 2:
See No. 2, No. 4, No. 5, No. 6, and No. 7 in the table below.
When using Method 3:
See No. 2, No. 5, No. 6, and No. 7 in the table below.
Table 97 How to obtain parameter values (AddConfigFileForReplication command)
How to obtainParameter nameNo.
Execute the GetHost command with the host name indicated below
specified for the hostname parameter.
When managing copy pairs by using local management
Specify the host on which the RAID Manager instance that manages the
P-VOL is installed.
When managing copy pairs by using central management
Specify the host that centrally manages copy pairs.
The execution result of the GetHost command displays the values of
groupName, pvolHostID, pvolInstanceNumber, svolHostID, and
svolInstanceNumber under An instance of ReplicationGroup.
See the output under the line that reads An instance of
ReplicationGroup for which the target group name is displayed as the
groupName value. The values displayed in the execution result correspond
to the parameter values as follows:
The pvolHostID value corresponds to the pvolhostid parameter
value.
The pvolInstanceNumber value corresponds to the pvolinstan-
cenum parameter value.
The svolHostID value corresponds to the svolhostid parameter
value.
The svolInstanceNumber value corresponds to the svolinstan-
cenum parameter value.
pvolhostid
svolhostid
pvolinstancenum
svolinstancenum
groupname
1
Execute the GetHost command with the host name indicated below
specified for the hostname parameter.
When managing copy pairs by using local management
To obtain the pvolhostid parameter value, specify the host on which
the RAID Manager instance that manages the P-VOL is installed.
To obtain the svolhostid parameter value, specify the host on which
the RAID Manager instance that manages the S-VOL is installed.
The execution result of the GetHost command displays the hostID
value under An instance of Host. If you execute the command by
specifying the host on which the RAID Manager instance that manages
the P-VOL is installed, the hostID value corresponds to the pvolhostid
parameter value. If you execute the command by specifying the host on
which the RAID Manager instance that manages the S-VOL is installed,
the hostID value corresponds to the svolhostid parameter value.
When managing copy pairs by using central management
Specify the host that centrally manages copy pairs.
The execution result of the GetHost command displays the hostID
value under An instance of Host. The hostID value corresponds
to the pvolhostid and svolhostid parameter values.
pvolhostid
svolhostid
2
Device Manager CLI command reference256