HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

How to obtainParameter nameNo.
Execute the GetStorageArray (subtarget=LogicalUnit) with
LogicalUnit specified for the subtarget parameter and the object ID
of the logical unit to be used as the P-VOL or the S-VOL (the object ID
recorded in No. 5) specified for the objectID parameter.
The execution result of the GetStorageArray
(subtarget=LogicalUnit) command displays the specified object ID
under An instance of LogicalUnit. See the values of arrayType,
displayArrayType, and serialNumber under An instance of
StorageArray that includes below it An instance of LogicalUnit
for which the specified object ID is displayed.
If you execute the command with the object ID of the logical unit to be used
as the P-VOL specified, the value of arrayType or displayArrayType
corresponds to the pvolarraytype parameter value, and the value of
serialNumber corresponds to the pvolserialnum parameter value.
Likewise, if you execute the command with the object ID of the logical unit
to be used as the S-VOL specified, the value of arrayType or
displayArrayType corresponds to the svolarraytype parameter
value, and the value of serialNumber corresponds to the
svolserialnum parameter value.
If the copy type of the copy pair to be created is Continuous Access
Asynchronous Software, Snapshot, or Continuous Access Journal Software,
record the values of the pvolarraytype, pvolserialnum,
svolarraytype, and svolserialnum parameters.
pvolarraytype
pvolserialnum
svolarraytype
svolserialnum
6
Execute the GetStorageArray (subtarget=Pool) with Pool specified
for the subtarget parameter, the model name specified for the model
parameter, and the serial number specified for the serialnum parameter.
The execution result of the GetStorageArray (subtarget=Pool)
command displays the values of poolFunction and PoolID under An
instance of Pool.
If you execute the command with the values of pvolarraytype and
pvolserialnum recorded in No. 6 specified for the model and
serialnum parameters, see the output under the line that reads An
instance of Pool for which the poolFunction value is the same as
the type of copy pair to be created. The poolID value corresponds to the
pvolpoolid parameter value.
If you execute the command with the values of svolarraytype and
svolserialnum recorded in No. 6 specified for the model and
serialnum parameters, see the output under the line that reads An
instance of Pool for which the poolFunction value is the same as
the type of copy pair to be created. The poolID value corresponds to the
svolpoolid parameter value.
pvolpoolid
svolpoolid
7
Command execution example 1
This example adds pairs to the existing group in the configuration files:
hdvmcli AddConfigFileForReplication -o "D:\logs\AddConfigFileForReplication.log"
"groupname=group1" "pvolhostid=1" "pvolinstancenum=11" "svolhostid=1"
"svolinstancenum=12" "pvolarraytype=XP12000" "pvolserialnum=65010001"
"pvoldevnum=5" "svolarraytype=XP12000" "svolserialnum=65010012"
"svoldevnum=10" "replicationfunction=ContinuousAccessSync"
CLI Reference Guide 259