HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

svolHostID=2
svolInstanceNumber=12
svolPortNumber=50,002
pvolHORCMMONHostName=192.168.32.63
svolHORCMINSTHostName=192.168.32.64
replicationFunction=ContinuousAccessSync
fenceLevel=Never
copyTrackSize=15
List of 1 ReplicationInfo elements:
An instance of ReplicationInfo
objectID=*****
pairName=HCMD_CP0004
pvolSerialNumber=65010001
pvolArrayType=XP1024
pvolDevNum=12
displayPvolDevNum=00:0C
pvolObjectID=*****
pvolPoolID=-1
svolSerialNumber=65010012
svolArrayType=XP1024
svolDevNum=25
displaySvolDevNum=00:19
svolObjectID=*****
svolPoolID=-1
fenceLevel=Never
replicationFunction=ContinuousAccessSync
status=8
muNumber=-1
copyTrackSize=15
splitTime=-1
remotePathGroupID=-1
*****: The values are encoded by the CLI.
Command execution example 2
This example deletes copy group 7 and all copy pairs defined in this copy group.
hdvmcli DeleteReplication -o "D:\logs\DeleteReplication.log"
"replicationgroupid=7"
Command execution result 2
RESPONSE
(Command completed; empty list returned)
GetReplicationControllerPair
GetReplicationControllerPair obtains information about a replication controller pair.
In P9500, XP24000/XP20000, XP12000/XP10000/SVS200, and XP1024/XP128, the pairs indicate
paths between MCUs and RCUs.
Device Manager CLI command reference274