HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

AddStorageArray on page 73
AddVirtualizationServer on page 218
GetHost on page 223
GetStorageArray (subtarget=CommParameters) on page 115
RefreshStorageArrays on page 190
Table 106 CommParameters instance attributes
DescriptionAttribute
User ID
One of the following values is output:
For a storage system:
User ID for accessing the storage system
For a virtualization server:
User ID for accessing the virtualization server or the virtualization-server
management program
userID
IP address
One of the following values is output:
For a storage system:
IP address of the storage system
For a virtualization server:
IP address of the virtualization server or the virtualization-server management
program
ipAddress
Second IP address of the storage system
ipAddress2
Protocol
One of the following values is output:
For a virtualization server:
Protocol of the virtualization server or virtualization server management pro-
gram
- Non-secure: HTTP communication
- Secure: HTTPS communication
For other cases, no value is output.
protocol
Port number
One of the following values is output:
For a virtualization server:
Port number of the virtualization server or virtualization server management
program
For other cases, no value is output.
portNumber
Device Manager CLI command reference286