HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

PDEV instance
The PDEV instance is output when the following commands are executed:
AddPool on page 65
GetStorageArray (subtarget=ArrayGroup) on page 111
GetStorageArray (subtarget=PDEV) on page 147
GetStorageArray (subtarget=Pool) on page 149
ModifyPool on page 170
Table 127 PDEV instance attributes
DescriptionAttribute
Object ID of the physical device
objectID
Drive name
This item is output if it has been registered.
name
Number of the chassis where the physical device exists
chassis
Parity group containing the physical device
-1 is output if the physical device does not belong to the parity group.
arrayGroup
Drive size of the physical device (in KB)
The following shows how to calculate the value that is output as Disk Size:
For P9500, XP24000/XP20000, or XP12000/XP10000/SVS200:
The capacity that is calculated by treating 1,024 bytes as 1 KB is output.
For XP1024/XP128:
The capacity that is calculated by treating 1,000 bytes as 1 KB is output.
capacityInKB
Physical horizontal position of the physical device
-1 is output for P9500, XP24000/XP20000, XP12000/XP10000/SVS200, or
XP1024/XP128.
row
Physical vertical position of the physical device
-1 is output for P9500, XP24000/XP20000, XP12000/XP10000/SVS200, or
XP1024/XP128.
column
Currently, this information does not apply to storage systems (-1 is output).denseNumber
Currently, this information does not apply to storage systems (-1 is output).densePosition
Currently, this information does not apply to storage systems.
depth
This item is not output.
role
This item is not output.
vendor
Drive model
model
Physical device firmware version
This item is not output for P9500, XP24000/XP20000,
XP12000/XP10000/SVS200, or XP1024/XP128.
firmwareVersion
CLI Reference Guide 309