HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

DescriptionAttribute
Type of the drive
If the storage system is P9500 and a pool for Thin Provisioning Software is used,
one of the following values is output:
-1: Unknown or a different drive type
1: SATA
4: SAS
5: SSD
This information is invalid for other cases (-1 is output).
diskType
Indicates whether the pool is a pool for Smart Tiers.
One of the following values is output:
enable: pool for Smart Tiers
disable: pool for Thin Provisioning Software
tierControl
Indicates whether the automatic execution of performance monitoring and hardware
tier relocation is enabled.
This attribute is valid only when a pool for Smart Tiers is used.
enable
disable
autoMigration
Execution cycle of performance monitoring and hardware tier relocation
This attribute is valid only when a pool for Smart Tiers is used, and tierControl
is enable.
0: 30 minutes
1: 1 hour
2: 2 hours
4: 4 hours
8: 8 hours
24: 24 hours
migrationInterval
Start time of performance monitoring (example: 00:00)
This attribute is valid only when a pool for Smart Tiers is used, and
migrationInterval is 24.
monitorStartTime
End time of performance monitoring (example: 23:59)
This attribute is enabled only when a pool for Smart Tiers is used, and
migrationInterval is 24.
monitorEndTime
Performance monitoring mode.
This attribute is valid only when a pool for Smart Tiers is used.
One of the following values is output:
0: Periodic
1: Continuous
monitoringMode
Device Manager CLI command reference314