HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

DescriptionAttribute
Total size of the logical units to which paths are not assigned (in GB)
freeCapacityInGB
Total size of the logical units to which paths are assigned (in GB)
allocatedCapacity-
InGB
Total size of the logical units reserved for Auto LUN Software (in GB)
autoLunCapacityInGB
Total size of the LDEVs expanded on demand (in GB)
onDemandCapacity-
InGB
Total size of the areas (free areas) that are not logical units (in GB)
For P9500, XP24000/XP20000, or XP12000/XP10000/SVS200, this calculation
is also performed for external volume parity groups.
totalFreeSpaceInGB
Maximum size of the area (free area) that is not a logical unit (in GB)
For P9500, XP24000/XP20000, or XP12000/XP10000/SVS200, this calculation
is also performed for external volume parity groups.
largestFreeSpace-
InGB
Total size of storage systems (in KB)
capacityInKB
Total size of the logical units to which paths are not assigned (in KB)
freeCapacityInKB
Total size of the logical units to which paths are assigned (in KB)
allocatedCapa-
cityInKB
Total size of the logical units reserved for Auto LUN Software (in KB)
autoLunCapacityInKB
Total size of the LDEVs expanded on demand (in KB)
onDemandCapa-
cityInKB
Total size of the areas that are not logical units (in KB)
totalFreeSpaceInKB
Maximum size of the area that is not a logical unit (in KB)
largest-
FreeSpaceInKB
Path support option
1 is output.
multipathSupport
Security status of the storage system
One of the following values is output:
-1: Unknown
0: No security
2: LUN Manager
securityStatus
Serial number or part of the serial number of the storage system
sequenceNumber
Display name of the storage system family
displayArrayFamily
Display name of the storage system type
displayArrayType
Number of logical units
numberOfLUs
Number of logical units to which paths are assigned
numberOfAllocated-
LUs
Device Manager CLI command reference328