HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

"1005,1003", "1005,1004", "1005,1005", "1005,1007", "1005,1018", "1005,1020",
"1005,1021", "1005,1025", "1005,1068", "1005,1134", "1005,1135", "1005,1350",
"1005,1363", "1005,1368", "1005,1600", "1005,1600", "1005,1904", "1005,6012",
"1005,6036", "1005,65660"
"2005,1002", "2005,1009", "2005,1010", "2005,1012", "2005,1013", "2005,1015",
"2005,1021", "2005,1028", "2005,1050", "2005,1126", "2005,1137", "2005,1182",
"2005,1185", "2005,1187", "2005,1196", "2005,1362", "2005,1365", "2005,1600",
"2005,1601", "2005,1904", "2005,1905", "2005,1921", "2005,2015", "2005,6012",
"2005,6036", "2005,65660", "2005,65672"
The configuration information of the Device Manager server and the configuration of the storage
system might not match. Perform the following procedure:
1. Execute the AddStorageArray command or RefreshStorageArrays command.
2. Execute the GetStorageArray command to check whether there is an error in the batch
file.
3. Correct any error in the batch file.
4. Execute the batch functionality again.
If you cannot still resolve this problem, collect the following information, and then contact your
HP Technical Support:
Device Manager CLI log file
Device Manager CLI properties file
Command line input
Batch file
Device Manager server log files
When the error code of the storage system is one of the following values:
"1005,1364", "1005,2009", "1005,2010", "1005,2013", "1005,2015", "1005,2032",
"1005,2082", "1005,2083", "1005,2098", "1005,2099", "1005,2500", "1005,2501",
"1005,3002"
"2005,2005", "2005,2009", "2005,2013", "2005,2032", "2005,2082", "2005,2083",
"2005,2084", "2005,2098", "2005,2099", "2005,2502", "2005,3002", "2005,3003",
"2005,3006"
Perform the following procedure:
1. Execute the AddStorageArray command or RefreshStorageArrays command.
2. Execute the GetStorageArray command to check which command lines in the batch file
were applied to the storage system.
The command processing during batch functionality execution is not performed in the order
described in the batch file. All lines need to be checked to determine which command lines
in the batch file were applied.
3. Delete the command lines applied to the storage system from the batch file.
4. Execute the batch functionality again.
When the error code of the storage system is one of the following values:
"1005,2005", "1005,2084", "1005,3003", "1005,3006"
Collect the following information, and then contact your HP Technical Support:
Device Manager CLI log file
Device Manager CLI properties file
Command line input
CLI Reference Guide 345