HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

Description
hostmodeoption
values
Specify this value when you are using XP12000/XP10000/SVS200 and both of the
following conditions are satisfied:
The host accesses a volume that exceeds 2 TB.
The host OS is one of the following:
- AIX 5L Version 5.2 TL08 or later, or AIX 5L Version 5.3 TL04 or later
- Windows Server 2003 SP1
- Red Hat Enterprise Linux AS 4 Update 1 or later
OSs other than above cannot access volumes that exceed 2 TB.
The maximum size of the volume varies, depending on the file system of the OS.
This value is valid when the XP12000/XP10000/SVS200 microcode version is
50-08-0X-XX/XX or later.
24
Specify this value when you are using P9500 or XP12000/XP10000/SVS200 and an
iSCSI connection.
27
Specify this value when you are using P9500 or XP24000/XP20000 and both of the
following conditions are satisfied:
The host mode is set to HP (mode 03), OpenVMS (mode 05), or Tru64 (mode 07).
You want to enable the commands that set a nickname for a device.
33
Specify this value when you are using P9500 or XP24000/XP20000 and both of the
following conditions are satisfied:
The host mode is set to Windows (mode 0C) or Windows Extension (mode 2C).
After increasing the volume capacity for Thin Provisioning Software, you want to
force that capacity to be automatically recognized.
40
Specify this value when you are using P9500 or XP24000/XP20000 and want to prior-
itize commands that force devices to be recognized.
41
Specify this value when you are using P9500 or XP24000/XP20000 and want to use
IBM Z10 Linux.
42
Specify this value if you want to force QueueFull to be the reply to a host when the
queue for P9500 or XP24000/XP20000 is full.
43
Specify this value when you are using XP24000/XP20000 and both of the following
conditions are satisfied:
External Storage Availability Manager is used.
You do not want a failover to occur from the MCU to the RCU when an application
is executed, for which the number of Read commands to be issued to the secondary
volume is equal to or more than the threshold value.
48
BB Credit Set Up Option1
Specify this value when you are using XP24000/XP20000 and want to use BB Credit
virtualization to improve True Copy performance.
49
BB Credit Set Up Option2
Specify this value when you are using XP24000/XP20000 and want to use BB Credit
virtualization to improve True Copy performance.
50
Device Manager CLI command reference52