HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1-01 Release Notes (TB581-96070, September 2011)

Creating logical groups
When the OK button is continuously clicked in the Create Logical Group dialog box, logical groups
that have the same name might be created. In this case, delete the extra names.
Upgrading Command View Advanced Edition to 7.1.0, or importing Command View
Advanced Edition 7.0.0 database
When either of the following conditions is met, the KAIC16029-E message might be displayed.
Command View Advanced Edition 7.0.0 is upgraded to Command View Advanced Edition 7.1.0.
Command View Advanced Edition 7.1.0 is installed, and then Command View Advanced Edition
7.0.0 database is imported.
If this occurs, restart the Device Manager service.
Replication Manager and viewing copy group information
The Visible/Total column in the Copy Group Summary (in the Pair Configurations view of Replication
Manager) sometimes displays a different value than the number of copy pairs displayed in the Pairs
tab.
The total number of copy pairs displayed in the Pairs tab is the actual number of viewable copy pairs.
This issue occurs when all of the following conditions are met:
No Replication Manager license is registered, and Replication Manager is started from Device
Manager.
From the Pair Configurations view (accessible by ExplorerResourcesPair Configurations, the
Copy Pair Summary is viewed (accessible by selecting Pair ConfigurationsPair Management
ServersConfig FilesCopy Groups.
Copy pairs that cannot be viewed are in the previously selected copy group.
Shrinking a pool
An unexpected error (KAIC60003-E) might appear without the message when using shrink pool.
If this occurs, confirm if the task of shrink pool has completed in Element Manager. If the shrink pool
task has completed in Element Manager, execute the format task.
Refresh the storage system by using the P9000 Command View Advanced Edition Software after the
format task completes.
Creating a pool
The error message Failed:AsynchronousProcessCounter#decrement (KAIC16993-E)
might appear when one of the following operations is continuously performed in the Create Pool dialog
box.
Addition of tiers
Deletion of tiers
Addition of parity groups
Deletion of parity groups
If this occurs, close the Create Pool dialog box, and then retry the operation.
14 Important considerations