HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1-01 Release Notes (TB581-96070, September 2011)

Loading a Plug-in for Virtualization Server Provisioning window
A dialog box with the message Are you sure you want to navigate away from this
page? might be displayed while the Plug-in for Virtualization Server Provisioning was used.
If this occurs, select the Cancel button on the dialog box.
Displaying the Plug-in for Virtualization Server Provisioning hosts for the first time
When VMware vCenter Server 4.1 is used, it might take some time to display the hosts when the hosts
are displayed for the first time after login.
Wait several minutes because Device Manager information is synchronizing with VMware vCenter
Server information.
Displaying information on Plug-in for Virtualization Server Provisioning and VMware
vSphere Client
Some information on a datastore or a virtualization server displayed on the Plug-in for Virtualization
Server Provisioning might be different from the information displayed on the VMware vSphere Client.
The CIM server uses the Pegasus service to allow connections from a CIM client. The Device Manager
works as a CIM client to manage VMware.
If this occurs, restart the Pegasus service in the vMA, and ask a storage administrator to refresh the
information on the virtualization server that Device Manager manages.
KAIC07661-E error in Plug-in for Virtualization Server Provisioning
When the Add Storage operation is performed, if the KAIC07661-E error occurs and the VMware
vSphere API name embedded in the message is QueryVmfsDatastoreCreateOptions, the
condition of volumes might be invalid.
Change the specified condition of the Add Storage operation or ask Storage Administrator to delete
the volumes and create a new volume.
KAIC07663-E in Plug-in for Virtualization Server Provisioning
When the Add Storage operation is performed, the KAIC07663-E message might be displayed if a
volume is tried to be allocated beyond the maximum number that is recognizable storage devices by
the VMware ESX Server.
Confirm the maximum number of recognizable storage devices by the VMware ESX Server, and then,
after unallocating the volumes from the VMware ESX Server, perform the Add Storage operation again.
Changing the access port number of the HBase Storage Mgmt Web Service
To change the access port number of the HBase Storage Mgmt Web Service, do not specify the
following ports:
1(tcpmux)
7(echo)
9(discard)
11(systat)
13(daytime)
15(netstat)
17(qotd)
19(chargen)
20(FTP Data)
Important considerations 23