HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1-01 Release Notes (TB581-96070, September 2011)

LocationSymbolic link destination
Under /var/opt/ CVXPAE /database/HTSM
3
Installation directory for the Tiered Storage Manager server
database and any directories
Under /var/opt/ CVXPAE /database/HRpM
3
Installation directory for the Replication Manager server
database and any directories
3
This is the default installation directory.
Permissions for the directory
Grant all users read and execution permissions to the installation directory, as well as all directories
below it. In Linux, the directory specified as the installation directory will have its permissions set to
775. Specify an installation directory for which there will be no issues if the permissions are changed
to 775.
Editing LDEV labels
When LDEV labels are edited in the Device Manager GUI, the following characters cannot be used
for LDEV labels.
*, |, :, ;, <, >, ,(comma), ?, /
If it is necessary to use above characters, set LDEV labels by using the CLI ModifyLabel command.
LDEV labels already including the characters can be continue to be used. However, the LDEV labels
cannot be set again with the characters.
Edit Label - object-name dialog box
When the Edit Label-object-name dialog box is displayed from the following windows, if the object
name does not use A - Z, a - z, 0 - 9, !, #, $, %, &, ', (, ), +, -, ., =, @, [, ], ^, _, {, }, or ~, the dialog
box is not displayed correctly.
Host-name subwindow
Virtualization-server-name subwindow
Virtual-machine-name subwindow
External-port-name subwindow
If this occurs, edit the LDEV label to use the correct character set.
About merging hosts
The Merge Host - host-name dialog box and the dialog box for confirming the merging of hosts are
not displayed correctly if the name of a host in the source host list does not use one of the following
characters:
A - Z, a - z, 0 - 9, !, #, $, %, &, ', (, ), +, -, ., =, @, [, ], ^, _, {, }, or ~.
About adding virtualization servers
The Add Virtualization Server - Completed dialog box is not displayed correctly if the name of a host
in the virtualization server list does not use any of the following characters:
A - Z, a - z, 0 - 9, !, #, $, %, &, ', (, ), +, -, ., =, @, [, ], ^, _, {, }, or ~.
Property setting for linking to Host Data Collector
When you install Command View Advanced Edition Suite on a computer containing only Host Data
Collector, the properties must be set for the connection between Device Manager and Host Data
Collector.
32 Important considerations