HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1-01 Release Notes (TB581-96070, September 2011)

For details about setting the properties, see the HP StorageWorks P9000 Command View Advanced
Edition Suite Software Configuration Reference Guide.
Host Data Collector service
If the Bourne shell is used to install Host Data Collector or to start the service, logging out of the
management server causes the Host Data Collector service to stop. Therefore, use a shell other than
the Bourne shell to install Host Data Collector or start the service.
When the KAIC05607-E or KAIC06400-E error occurs during an operation to change
a storage system configuration
If the KAIC05607-E or KAIC06400-E error occurs when changing a storage system configuration
in the Device Manager GUI or CLI, some of the configuration changes might have been applied to
the storage system. Refresh the storage system information and check the current storage system
configuration. After that, continue the configuration change operation by using the Device Manager
GUI, CLI, or Element Manager.
Installing the Device Manager agent in Red Hat Enterprise Linux 6(x64)
In Red Hat Enterprise Linux 6(x64), an installation of Device Manager agent is not successful if
glibc-<RPM-package-version>.i686.rpm is not installed in the target machine (when a silent
installation of Device Manager agent is performed, the output return code will be 144).
If this occurs, reinstall the Device Manager agent after the package is installed.
When the port necessary for the HCS Device Manager Web Service is used, HCS
Device Manager Web Service cannot be started and Internal Server Error is displayed
on the GUI Login screen
Port number 23025, necessary for HCS Device Manager Web Service, may be used by another
process. This depends on the system where Device Manager installed, because port number 23025
is within the range of ports that the operating system dynamically allocates.
If this occurs, add the port number 23025 to the services file managed by the operating system.
For Windows:
%windir%\system32\drivers\etc\services
For Linux:
/etc/services
Using the Device Manager CLI with the French version of Windows
When using the Device Manager CLI, the comma used in a numerical value (such as 123,456,789)
of the output is not allowed in the French version of Windows.
Change the setting of the command prompt as follows.
1. Set the font from Properties of the command prompt to Lucida Console.
2. Execute the command line chcp 1252 in the command prompt.
SMI-S Indication function
In interop namespace, only the query described in SMI-S1.3 can be set for the Query property of
CIM_IndicationFilter.
Important considerations 33