HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1-01 Release Notes (TB581-96070, September 2011)

An attempt to delete the host was not successful and generated the KAIC15316-E error.
An attempt to edit the LUN paths was not successful and generated the KAIC15000-E error.
If you upgraded the P9000 Command View Advanced Edition Suite, the version of Host Data
Collector or Application Agent available from the download screen might be a version older than
your current version.
When a volume belonged to a host group with a name of 33 or more characters and the volume
was allocated, unallocated, virtualized, or a path was edited in GUI; the KAIC15000E error
occurred and the operation did not continue.
When the CIM/WBEM function was used, the performance information on volumes might not
have been obtained. If the performance information on volumes was not obtained, a client using
the CIM/WBEM function received the following message:
Error code: 1
Error description: Attempt to begin transaction while already in a transaction
When expanding a THP volume, the KAIC16188-E error message did not appear and the
KAIC16189-W error message appeared if the subscription of a pool exceeded the subscription
limit with the specified new capacity.
In the list of the Tiered Storage Manager GUI and the results of the CLI getVolumes command
in Tiered Storage Manager, volumes for non-migration candidates were displayed as migration
candidates.
Important considerations
VMware ESX 4.0 or later and VMware ESXi 4.0 or later
When using VMware ESX 4.0 or later, or VMware ESXi 4.0 or later, note the following:
Device Manager:
After configuring or releasing a command device, or after changing the P-VOL or S-VOL
configuration, if the hldutil command is executed on a virtual machine, the information displayed
for the command device, P-VOL, and S-VOL might be incorrect. Check the command device column
in the Host window of the Device Manager GUI to confirm the command device information.
Also, check the Copy Role column in the Host window of the Device Manager GUI to confirm the
P-VOL/S-VOL information.
If the hldutil command of the Device Manager agent is executed on the virtual machine,
information about the physical WWN will be displayed. Check the World Wide Names/iSCSI
Names column in the Host window of Device Manager GUI to confirm the WWN of the virtual
machine.
Replication Manager:
The Replication Manager command device configuration function cannot be used to set a volume as
a command device if the volume has been allocated for a virtual machine.
1. Use P9000 Remote Web Console to set the volume as a command device.
2. Use P9000 Remote Web Console to add the command device in step 1 to a VMware host group,
and ensure that a path is set for the command device.
3. Perform VMware Raw Device Mapping and ensure that the command device in step 1 is recognized
by the virtual machine.
Important considerations 7