HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1-01 Release Notes (TB581-96070, September 2011)

When modifying them, use the Add Resource Groups dialog box, the Edit Roles dialog box, or the
Remove Resource Groups dialog box in the resource group details window.
Expanding THP Volumes
When selecting some THP volumes and specifying a value for the New Capacity in the Expand THP
Volumes dialog, an unexpected error (KAIC16009-E) might be displayed. In this case, log in again
if needed, reduce the number of specified THP Volumes, and retry the operation.
Creating and allocating THP volumes
In the Allocate Volumes dialog box or the Create Volumes dialog box, displaying the Select THP Pool
dialog might take several minutes when clicking the Select Pool button with volume types that satisfy
all of the following conditions:
Storage system is P9500 or XP24000/XP20000
Volume type is Thin Provisioning or Smart pool
The total number of THP pool volumes above is 100 or more
If displaying Select THP Pool dialog takes over 5 minutes, the KAIC16009-E error occurs.
If this occurs, select a target THP pool in THP pool list, and then select the Create Volumes or Allocate
Volumes button.
Task detail dialog box of editing tiering policy
The value of the tiering policy in the task detail dialog is not displayed after completing the editing
tiering policy task.
Enter the value of the tiering policy in the task name or description field when creating the editing
tiering policy task.
Task execution of storage system configuration changes
Even though a task that changes the storage system configuration succeeded, the task status might
appear as Failed with the error KAIC08107-E. If this occurs, display the task details dialog box
and the resources tab, and check whether the task succeeded.
This symptom might occur when both of the following conditions are met:
The type of task is one of the following:
Create Pool
Expand Pool
Shrink Pool
Create Volume
Expand THP Volume
The target storage system of the task is any of the following:
P9500
XP24000/XP20000
XP12000/XP10000/SVS200
XP1024/XP128
Important considerations 9