HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

Setting up Device Manager to output SNMP traps
To set up Device Manager to receive SNMP traps and output them to log files, the following settings
must be specified:
Settings required for Device Manager to receive SNMP traps
Device Manager must be able to use port 162/udp of the management server.
The management server information must be registered in SNMP related software as the target
for trap notification.
For example, to receive storage system SNMP traps, SNMP Agent settings must be specified.
Specify true for the server.dispatcher.daemon.receiveTrap property.
Settings required to output received SNMP traps to log files
Specify true for the customizedsnmptrap.customizedSNMPTrapEnable property.
The output contents must be set in the customizedsnmptrap.customizelist property.
Specifying information to include in SNMP Traps
By using the customizedsnmptrap.customizelist property, you can specify the severity and
output format of SNMP traps to be recorded in log files.
Specify the items shown in the following table by separating them using a colon (:).
Table 43 Items specified in the customizedsnmptrap.customizelist property
RemarksFormatItem
Required
Specify by using dots (for example,
.1.3.6.1.4.116.3.11.1.2)
enterprise-
ID
RequiredNumeric value, from 0 to 6
generic-
trap-number
RequiredNumeric value
specific-
trap-number
This item is optional. If you omit this item, Null
is assumed.
The severity indicators in the message IDs are
output as follows:
-I for Information
-W for Warning
-E for Error, Critical, and Alert
No log data is output for Null
Specify the severity of each trap by using
one of the character strings below.
You cannot use character strings other
than the following:
Information
Warning
Error
Critical
Alert
Null
severity
Administrator Guide (Web Version) 129