1. Add Device Manager and Tiered Storage Manager resources to the resource group.
Select New, and then Resource. In each dialog box, specify the settings as shown in Table 57
to Table 62, and then select Finish.
Table 57 Settings for registering HiRDB as a resource (for Microsoft Cluster Service)
SettingDialog box name
Name: HiRDB/ClusterService _HD0 (optional)
New Resource
Resource type: Generic Service.
Make sure that the executing and standby nodes have been added.Possible Owners
Register the drive letter and network name of the shared disk.Dependencies
Service name: HiRDBClusterService_HD0
Generic Service Parameters
Start parameters: Specify nothing.
Specify nothing.Registry Replication
Table 58 Settings for registering the HBase Storage Mgmt Common Service as a resource (for
Microsoft Cluster Service)
SettingDialog box name
Name: HBase Storage Mgmt Common Service (optional)
New Resource
Resource type: Generic Service.
Make sure that the executing and standby nodes have been added.Possible Owners
Register HiRDB/ClusterService _HD0.Dependencies
Service name: HBaseStgMgmtComService
Generic Service Parameters
Start parameters: Specify nothing.
Specify nothing.Registry Replication
Table 59 Settings for registering the HBase Storage Mgmt Web Service as a resource (for Microsoft
Cluster Service)
SettingDialog box name
Name: HBase Storage Mgmt Web Service (optional)
New Resource
Resource type: Generic Service.
Make sure that the executing and standby nodes have been added.Possible Owners
Register HBase Storage Mgmt Common Service.Dependencies
Service name: HBaseStgMgmtWebService
Generic Service Parameters
Start parameters: Specify nothing.
Specify nothing.Registry Replication
Table 60 Settings for registering the HCS Device Manager Web Service as a resource (for Microsoft
Cluster Service)
Administrator Guide (Web Version) 171