HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

The following tables show the contents and specified items in a configuration definition file for each
parameter. For details about description rules for the content that can be specified, see Detailed
rules for configuration definition files on page 225.
Table 88 HORCM_MON parameter items and descriptions
DescriptionItem
Specify the IP address (the Device Manager agent whose version is 5.9 or later
supports the IPv6 protocol), host name, NONE, or NONE6.
Note that if you use Replication Manager to generate a configuration definition
file, this item will always be specified for the host name (Replication Manager uses
a Device Manager agent to view the configuration definition file).
ip_address
Specify the port name or port number.
service
Specify a value (in ten millisecond units) or -1.poll(10ms)
Specify the timeout period in ten millisecond units.
timeout(10ms)
Table 89 HORCM_CMD parameter items and descriptions
DescriptionItem
In Windows:
Specify the command device using the IPCMD format, PhysicalDrive format, GUID
format, or CMD format.
In UNIX:
Specify the command device using IPCMD format or a special file.
You can specify more than one command device in the same system, and you can specify
a command device in more than one system.
dev_name
Table 90 HORCM_DEV parameter items and descriptions
DescriptionItem
Specify the group name.
dev_group
Specify the name of the pair volume.
dev_name
Specify the port name.
port#
Specify the target ID of SCSI/Fibre.
targetID
Specify the LU number of SCSI/Fibre.
LU#
Specify the mirror descriptor using a numeric value or the h addition. You can omit this
by leaving it blank.
MU#
Table 91 HORCM_LDEV parameter items and descriptions
DescriptionItem
Specify the group name.
dev_group
Specify the name of the pair volume.
dev_name
Using and maintaining the Device Manager agent224