HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

DescriptionItem
Parity Group number
RG#
Port WWN
PortWWN
#3
Node WWN
NodeWWN
#3
iSCSI name for the iSCSI initiator
iSCSIName
#1:
If the host is a virtual machine on VMware ESX 4.x or VMware ESXi 4.x and you execute the
hldutil command after changing the configuration of the P-VOL or S-VOL, this information
might not be displayed correctly. In this case, restart the virtualization server to display the inform-
ation correctly.
#2:
In the case of HP-UX 11i v3, this item is not displayed for a persistent special device (persistent
device special file).
#3:
If the virtual WWN is assigned to the virtual machine on VMware ESX 4.x or VMware ESXi 4.x
by using NPIV, the physical WWN of the virtualization server is displayed.
The following table lists the correspondence between the string output for RaidID and the storage
system model.
Table 103 Correspondence between RaidID and storage system models
ModelRaidID
XP1024
R450
XP128
R451
XP12000
R500
XP10000
R501
SVS 200
R502
XP24000
R600
XP20000
R601
P9500
R700
javapath_setup command
The javapath_setup command is used to switch the Java execution environment used on the Device
Manager agent when the host OS is Windows or Linux. The javapath_setup command is stored
in the following location:
In Windows:
installation-folder-for-Device-Manager-agent\bin\javapath_setup.exe
In Linux:
/opt/HDVM/HBaseAgent/bin/javapath_setup.sh
Administrator Guide (Web Version) 241