HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

If you use the CLI to operate copy pairs, the required version of the Device Manager agent differs
depending on the program, operation, and storage system model to be used.
Table 9 Device Manager agent requirements for managing copy pairs by using the CLI
Device Manager agent
version
#
Operation from Device ManagerProgram
1.1 or laterDisplay the status
Continuous Access Journal
5.5 or laterDisplay the status (3DR)
5.6 or laterChange the status
5.5 or laterChange the status (3DR)
1.0 or laterDisplay the status
Continuous Access
1.0 or laterChange the status
1.0 or laterDisplay the status
Business Copy
1.0 or laterChange the status
1.0 or laterDisplay the statusSnapshot
Note:
To create a configuration definition file, Device Manager agent version 3.1 or later must be in-
stalled on each host.
#:
The following table lists the Device Manager agent version required for each storage system
model.
Table 10 Device Manager agent version required for each storage system model when managing
copy pairs by using the CLI
Device Manager agent versionStorage system model
7.0 or laterP9500
5.7 or laterXP24000
5.8 or laterXP20000
1.0 or later
XP12000
XP10000
XP1024
XP128
For details on the settings required in the Device Manager agent, see Managing copy
pairs on page 212.
Administrator Guide (Web Version) 59