HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Installation and Configuration Guide (TB581-96063, September 2011)

2 P9000 Command View AE Software
server installation
This module describes how to install the server.
Planning for server installation
Before you install the P9000 Command View AE Software server, verify the following conditions and
gather the information you need to perform the installation.
Verifying server installation conditions
Before using the installer for the P9000 Command View AE Software server, determine the information
you need to provide.
NOTE:
HP recommends accepting default values when available.
For a new installation, you need:
The installation destination path, in the format:
For Windows: \program-files-folder\CVXPAE
#
For Linux: /opt/CVXPAE
#
: program-files-folder indicates the following location:
For Windows (x86): The folder specified in the Windows system environment variable %Pro-
gramFiles%.
For Windows (x64 or IPF): The folder specified in the Windows system environment variable
%ProgramFiles(x86)%.
The storage destination path for database files, in the format:
For Windows: \installation-destination-path\database
For Linux: /var/installation-destination-path/database
Management server information:
Host name or IP address: Host name set for the OS
For all installations, you need:
Memory heap size
Installation and Configuration Guide 15