HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Installation and Configuration Guide (TB581-96063, September 2011)
Memory Heap Size
Managed ResourcesEnvironment
Large
(Min: 512 MB,
Max: 1,024
MB)
Medium
(Min: 256 MB,
Max: 512 MB)
Small
(Min: 128 MB,
Max: 256 MB)
60,001 or more
40,001 to
60,000
40,000 or less
Both open
volumes and
mainframe
volumes
#
Legend:
-- : You cannot specify this memory heap size.
#
If you manage both open volumes and mainframe volumes, use the following formula to calculate the number
of copy pairs:
number-of-open-system-copy-pairs x 6 + number-of-mainframe-system-copy-pairs
Table 4 Appropriate memory heap size for the Device Manager server
Memory Heap Size
Managed Re-
source
OS
Large
(Min: 128 MB, Max:
1,024 MB)
Medium
(Min: 128 MB, Max:
512 MB)
Small
(Min: 128 MB,
Max: 256 MB)
--2,001 to 6,0002,000 or less
The number of
volumes per stor-
age system
Windows (IPF)
6001 or more2,001 to 6,0002,000 or less
The number of
volumes per stor-
age system
OS other than
Windows (IPF)
--: You cannot use Device Manager to manage storage systems that have more than 6,000 volumes.
Related topics
• Verifying server installation conditions, page 15
• P9000 Command View AE Software server installation prerequisites, page 21
• Installing P9000 Command View AE Software in a Windows environment, page 31
• Installing P9000 Command View AE Software in a Linux environment, page 32
Prerequisites for database file backups or export locations
If P9000 Command View AE Software is already installed on the management server, create a copy
of the database using the method appropriate to the installed version before performing an upgrade.
• From a version earlier than 5.5: Back up the database.
• From version 5.5 or later: Export the database.
P9000 Command View AE Software server installation20