HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Installation and Configuration Guide (TB581-96063, September 2011)

Common Com-
ponent
HiRDB
Operating Sys-
tem Initial Value
Installer Check
Value
Shell Restriction
16551281928358nproc (soft/hard)
Table 9 Shell restriction values for /etc/security/limits.conf (2/2)
Replication Manager
Software
Tiered Storage Manager
Software
Device ManagerShell Restriction
000nofile (soft/hard)
001nproc (soft/hard)
The following formula is for calculating the values for the shell restriction:
shell-restrictions-value-to-be-set =
Max{
Max {
value-that-is-enabled-in-the-system
,
initial-value-of-the-OS
}
+ value-for-Common-Component
+ value-for-Device-Manager
+ value-for-Tiered-Storage-Manager
+ value-for-Replication-Manager
,
value-for-HiRDB
}
NOTE:
Max {x, y} indicates the larger value of x or y.
Related topics
Setting kernel parameters and shell restrictions (Linux), page 22
Recommended Red Hat Enterprise Linux /etc/sysctl.conf values, page 23
Modifying kernel parameter values and shell restrictions, page 30
Recommended SUSE Linux Enterprise Server /etc/sysctl.conf values
Before installing P9000 Command View AE Software on a SUSE Linux Enterprise Server system, set
the kernel parameters for the /etc/sysctl.conf file.
The appropriate values for each of these settings depend on which of the following P9000 Command
View AE Software products you are installing:
Common Component
Device Manager
Tiered Storage Manager Software
Replication Manager Software
P9000 Command View AE Software server installation26