HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Installation and Configuration Guide (TB581-96063, September 2011)

Default ValueDetailsProperty Name
FALSE
Specify whether to continue an
installation even if the host name or
IP address that was specified in
HINST_IPADDRESS is not
communicating with the network.
TRUE: Continue the installation
FALSE: Stop the installation.
HINST_IGNORE_NETWORK-
ING_CHECK
#1
program-files-folder indicates the following location:
For Windows x86: The folder specified in the Windows system environment variable %ProgramFiles%
For Windows x64 or IPF: The folder specified in the Windows system environment variable %ProgramFiles(x86)%
#2
When installing in a cluster environment, default values are not specified automatically. You must explicitly specify values. When
installing on the standby node, you do not need to specify this property.
#3
When installing in a cluster environment, you must specify this property on both the executing and standby nodes.
#4
If you perform an installation on the standby node in a cluster environment, databases are not backed up or exported.
#5
If you specify this property in a cluster environment, it is ignored.
Related topics
Prerequisites for server installation locations (new installations only), page 17
Prerequisites for database file storage locations (new installations only), page 18
Prerequisites for management server information, page 18
Determining memory heap size, page 19
Prerequisites for database file backups or export locations, page 20
Prerequisites for P9000 Command View AE Software server unattended
installation
Before performing an unattended installation of P9000 Command View AE Software server, review
system requirements information and perform the following tasks:
Run Tiered Storage Manager tasks when upgrading from 7.1.0 or earlier:
If there are incomplete tasks (standby, running, being cancelled), go to the Tasks & Alerts tab
and execute or cancel the tasks. After upgrading, register the canceled tasks as new.
Determine the values that are set during installation
Verify that the execution result file (HInstReport.txt) is closed.
The Prerequisite checker, downloaded from the installer, verifies whether the installation destination
satisfies the requirements.
For a complete list of system requirements, see the HP StorageWorks P9000 Command View Advanced
Edition Suite Software Release Notes and HP StorageWorks P9000 Tiered Storage Manager Software
CLI Reference Guide.
Related topics
Verifying server installation conditions, page 15
P9000 Command View AE Software server installation prerequisites, page 21
Installing the server in a Windows environment (unattended installation), page 68
Installation and Configuration Guide 67