HP StorageWorks P9000 Tiered Storage Manager Software 7.1.0-02 Release Notes (TB585-96017, August 2011)

Corrections made in 7.1.0-01
None
Important considerations
Selecting a tier when creating a migration plan
Do not select a tier with more than 1,300 free volumes when creating a migration plan.
When a tier created from the Device Manager GUI is displayed on Tiered Storage
Manager
When a tier created from the Device Manager GUI meets any of the following conditions, the tier is
not displayed in the storage tiers of Tiered Storage Manager:
The tier was created by directly specifying 101 or more volumes.
The tier was created by selecting either of the following attributes in the advanced search criteria
and by specifying 101 or more values for the attribute:
ID/Number/Name is specified for the category, and the Parity group on a controller that
hosts can access is specified for the attribute.
ID/Number/Name is specified for the category, and the Parity group on a controller that
contains drives is specified for the attribute.
Message about refreshing the storage domain
Substitute messages directing to Refresh the storage domain or Refresh Tiered Storage
Manager with Refresh the storage system.
Determine the name of the storage system corresponding to the storage domain using one of the
following methods:
Using the GUI:
In the <storage-domain-name> subwindow, on the Detailed Information tab, refer to the first
value of Domain Ctrl.
In Domain Ctrl, the display format of the storage system is
<storage-system-name>:<model-name>:<serial-number>.
Using the CLI:
Refer to the controllerName value in the output of the command GetStorageDomains -d.
Mozilla 1.7.13 (HP-UX 11i v3) support
If the Tiered Storage Manager GUI uses Mozilla 1.7.13 in HP-UX 11i v3 for PA-RISC, the IPv6 protocol
cannot be used to communicate with the Device Manager server.
Prerequisites
Applicable product version
7.1.0-00 to 7.1.0-01
4 Important considerations