HP StorageWorks XP Command View Advanced Edition software Device Manager server installation and configuration guide (web version) (T1780-96078, March 2008)

Device Manager server properties
191
Table 8-1 Summary of Device Manager property files
Property Description Location
server.dispatcher.e
ndTimeOfIgnoringCon
nectionAlert
Defines the end time of the interval for stopping SNMP
communication alerts.
subsection
8-5-
7
server.dispatcher.d
aemon.receiveTrap
Determines whether or not port 162 is used as an SNMP
trap.
subsection
8-5-
8
MIME properties
These properties contain the translation/lookup table for all
Multipurpose Internet Mail Extensions (MIME) file types
recognized by the Device Manager web server.
section
8-6
Client properties
These properties affect the configuration of Device
Manager web client.
section
8-7
client.logger.trace
Defines whether or not to output trace log information.
subsection
8-7-
1
client.message.time
out
Defines the maximum wait time for the Device Manager
server response (timeout of connection) in seconds.
subsection
8-7-
2
client.outputhorcmf
unction.enabled
Specifies whether to enable web client to use an XP RAID
Manager function for creating a configuration definition file.
subsection
8-7-
3
table.ldev.rowsperp
age
Specifies the values displayed in the drop-down list used
for setting the number of lines displayed per page on a
window using a web client sortable table.
subsection
8-7-
4
client.assignlun.up
perlimit.enabled
Enables you to make the upper limit check enabled or
disabled for the number of LUNs that are assigned when
storage is added.
subsection
8-7-
5
client.report.csv.f
ormat.escaped
Enables you to switch the format of the CSV report for
information of the storages and users that are managed by
Device Manager.
subsection
8-7-
6
SNMP trap log output
function properties
These properties include whether to allow Device Manager
to use SNMP traps, and whether the trap list will be
customized.
section
8-9
customizedsnmptrap.
customizedSNMPTrapE
nable
This property allows you to enable the SNMP trap log
output function.
subsection
8-9-
1
customizedsnmptrap.
customizelist
This property allows you to specify how to customize the
SNMP trap log output.
subsection
8-9-
2
Mainframe host agent
properties
These properties include settings for communication
between the Device Manager server and mainframe hosts.
section
8-10
host.mf.agent.conne
ction.timeout
Specifies the timeout for communication processing with a
host agent.
subsection
8-
10-1
Report function
properties
These properties include the properties for using the report
function.
subsection
8-11
DetailedArrayReport
.outputPath
Specifies the location of Detailed Array Reports files (in
CSV format) created by web client.
subsection
8-
11-1
8-2 Server configuration properties
The server configuration properties are contained in the server.properties file.