HP StorageWorks XP Command View Advanced Edition software Device Manager server installation and configuration guide (web version) (T1780-96078, March 2008)

Device Manager network configuration
36
2-3 Working with a network that uses a firewall
If a firewall is set up between the management server and other objects (such as the management
client, managed host, storage subsystem, or CIM [Common Information Module] client), set the
firewall to allow communication through each port, as detailed in
Table 2-1 to Table 2-4.
If a firewall is set up between the management client (web client) and a storage subsystem, set the
firewall to allow communication through each port, as detailed in
Table 2-6.
Table 2-1 Ports used for communication between the management server and a management
client
Port
number
Originator Destination Remarks
23015/tcp
*
Management client
(web client)
Management server This setting is required when
non-SSL communication is
used.
23016/tcp
*
Management client
(web client)
Management server This setting is required when
SSL communication is used.
2001/tcp
*
Management client
(web client or CLI)
Management server This setting is required when
non-SSL communication is
used.
2443/tcp
*
Management client
(web client or CLI)
Management server This setting is required when
SSL communication is used.
* This port number can be changed.
Table 2-2 Ports used for communication between the management server and a managed host
Port number Originator Destination Remarks
24041/tcp
*
Management server Managed host When the managed host is a
mainframe host, this setting is
not required.
24042/tcp
*
Management server Managed host -
2001/tcp
*
Managed host Management server When the managed host is a
mainframe host, this setting is
not required.
* This port number can be changed.
Table 2-3 Ports used for communication between the management server and storage
subsystems
Port
number
Originator Destination Remarks
21/tcp
Management server
XP512/XP48
XP1024/XP128
XP12000/XP10000/SVS200
XP24000/XP20000
-
20/tcp
XP512/XP48
XP1024/XP128
XP12000/XP10000/SVS200
XP24000/XP20000
Management server Set the firewall so that
communication can be
established from 20/tcp
port of the storage
subsystem to any port of
the management server.