HP StorageWorks XP Provisioning Manager User Guide (December 2005)

Troubleshooting 195
Table 11-17 Provisioning Manager Agent Messages (continues on the following pages)
Error Code Error Message Description and Recommended Action
Action: No action is required.
KARF65012-I The cfgmgr command will be executed
number of command execution times.
Cause: -
Action: No action is required.
KARF65013-E The specified raw device still exists. Cause: The specified raw device was not correctly
deleted from the host.
Action: Delete the specified raw device from the
host, and then resume processing.
KARF65014-E An unnecessary device file exists. Cause: The specified raw device was not correctly
deleted from the host.
Action: Delete the specified raw device from the
host, and then resume processing.
KARF66001-E VolumeManagerAdmin execution error. Cause: An unexpected internal error occurred.
Action: Acquire the error information for
Provisioning Manager and Device Manager, and
then contact the Support Center.
KARF66002-E FileSystemAdmin execution error. Cause: An unexpected internal error occurred.
Action: Acquire the error information for
Provisioning Manager and Device Manager, and
then contact the Support Center.
KARF66003-E RawDeviceAdmin execution error. Cause: An unexpected internal error occurred.
Action: Acquire the error information for
Provisioning Manager and Device Manager, and
then contact the Support Center.
KARF66004-E The specified volume manager type is not
supported.
Cause: The Agent information recognized by the
Provisioning Manager server has not been
updated.
Action: Refresh the host information, and then retry
the operation.
KARF66005-E The specified file system type is not
supported.
Cause: The Agent information recognized by the
Provisioning Manager server has not been
updated.
Action: Refresh the host information, and then retry
the operation.
KARF66006-E The specified raw device does not exist. Cause: The specified raw device is not correctly
recognized as a device file on the host.
Action: Make the specified raw device
recognizable as a device file, and then resume
processing.
KARF66007-E The raw device cannot be deleted because
there is a partition in the raw device.
Cause
Partitions exist on the specified raw device.
Action
Delete all partitions in the raw device if they
are not being used, and then retry the
operation.
KARF66008-E The character * cannot be used. Cause
The request was made with an invalid value.
Action
Acquire the error information for Provisioning
Manager and Device Manager, and then
contact the Support Center.
KARF66009-E An md device already exists on the specified
device file.
Cause
An unsupported device file was specified.
Action
Delete the md device, and then retry the
operation.
KARF67001-E The md device cannot be created because a
system limit was exceeded.
Cause
The number of md devices exceeded a
system limit.
Action
Delete an unnecessary md device, and then
retry the operation.