HP StorageWorks XP Provisioning Manager User Guide (December 2005)

Troubleshooting 198
Table 11-18 Messages Common to Provisioning Manager Components
Error Code Error Message Description and Recommended Action
KARF99000-W The value specified for
logger.MaxBackupIndex in logger.properties
is invalid, so the default value will be set and
used for startup.
Cause: An invalid value is set for the setting
logger.MaxBackupIndex in the property file
logger.properties.
Action: Check the value of logger.properties.
KARF99001-W The value specified for logger.MaxFileSize in
logger.properties is invalid, so the default
value will be set and used for startup.
Cause: An invalid value is set for the setting
logger.MaxFileSize in the property file
logger.properties.
Action: Check the value of logger.properties.
KARF99002-W The value specified for logger.sysloglevel in
logger.properties is invalid, so the default
value will be set and used for startup.
Cause: An invalid value is set for the setting
logger.sysloglevel in the property file
logger.properties.
Action: Check the value of logger.properties.
KARF99003-W The value specified for logger.loglevel in
logger.properties is invalid, so the default
value will be set and used for startup.
Cause: An invalid value is set for the setting
logger.loglevel in the property file
logger.properties.
Action: Check the value of logger.properties.
KARF99004-I A value for logger.MaxBackupIndex in
logger.properties is not specified, so the
default value will be set and used for startup.
Cause: A value for logger.MaxBackupIndex in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.
KARF99005-I A value for logger.MaxFileSize in
logger.properties is not specified, so the
default value will be set and used for startup.
Cause: A value for logger.MaxFileSize in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.
KARF99006-I A value for logger.sysloglevel in
logger.properties is not specified, so the
default value will be set and used for startup.
Cause: A value for logger.MaxFileSize in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.
KARF99007-I A value for logger.loglevel in logger.properties
is not specified, so the default value will be
set and used for startup.
Cause: A value for logger.loglevel in
logger.properties is not specified.
Action: If necessary, specify the value in
logger.properties.
KARF99008-W An attempt to load the logger.properties file
has failed. The default values for all settings
will be set and used for startup.
Cause: The property file (logger.properties) could
not be read.
Action: Check the logger.properties file.