HP XP7 Command View Advanced Edition Mainframe Agent Installation and Configuration Guide (TK981-96005, May 2014)

ActionEvent
Take appropriate action according to the return
code.
XP7 mainframe agent terminates with a return code other
than (00).
When information from XP7 mainframe agent is not updated
The table below lists the events and actions to be taken when information is acquired by using HP
XP7 Command View Advanced Edition product, but the information from XP7 mainframe agent is not
updated. In the Event column, go down in the order listed and locate the first description that matches
the event that is occurring, and then use the action in the Action column to solve the problem.
Table 23 Events and what to do when information from XP7 mainframe agent is not updated
ActionEvent
The specified port number is in use. Either terminate the pro-
gram that is using the port number or change the port number
in the initialization parameter, then restart XP7 mainframe
agent.
The following message is displayed: YKY330I
SOCKET API FAILURE (OPEN,BIND,-
0000001,0000048)
Protected by RACF. Check and, if necessary, revise the RACF
settings, then restart XP7 mainframe agent.
The following message is displayed: YKY330I
SOCKET API FAILURE (INIT,INITAPI,-
0000001,0000156)
Protected by RACF. Check and, if necessary, revise the RACF
settings, then restart XP7 mainframe agent.
The following message is displayed: YKY330I
SOCKET API FAILURE (OPEN,BIND,-
0000001,0000013)
Make sure that the user SVC has been registered, then restart
XP7 mainframe agent.
XP7 mainframe agent has terminated abnor-
mally with a system completion code (Fnn).
(Fnn: SVC number)
Take appropriate action according to the displayed message.
An error message is displayed on the console
or in SYSLOG.
Troubleshooting110