HP XP7 Command View Advanced Edition Mainframe Agent Installation and Configuration Guide (TK981-96005, May 2014)

Explanation and actionsMessage textMessage ID
Initialization parameters analysis failed due to a shortage
of work space. The XP7 mainframe agent will be terminated.
Check, and, if necessary, revise the specification of the user
region in the job step in the XP7 mainframe agent startup
cataloged procedure, correct the memory requirements, and
then restart the XP7 mainframe agent.
INSUFFICIENT SPACE
AVAILABLE FOR INITIAL-
IZATION
YKY008I CON
A task terminated abnormally during the XP7 mainframe
agent start up. The XP7 mainframe agent will be terminated.
task-ID
Name of the task
completion-code
System completion code
TASK(task-ID)
ABENDED,CODE=com-
pletion-code
YKY016I CON
The load module shown as load-module-name was not
found. The XP7 mainframe agent will be terminated.
Make sure that the indicated load module was installed
correctly.
MODULE(load-mod-
ule-name) NOT
FOUND
YKY018I CON
The DD statement shown as dd-name is missing. The XP7
mainframe agent will be terminated.
Specify the DD statement in the cataloged procedure used
for starting the XP7 mainframe agent and then restart the
XP7 mainframe agent.
dd-name DD STATE-
MENT NOT FOUND
YKY019I CON
The STGADMIN.YKA.BCM.YKQUERY or
STGADMIN.YKA.BCM.COMMANDS profile is not defined in
the FACILITY class of the RACF.
Review the RACF settings and then restart the XP7 mainframe
agent.
xxxxxxxx
Maintenance information
THE PROFILE IS NOT
DEFINED IN THE FACIL-
ITY CLASS OF RACF:
xxxxxxxx
YKY020I CON
The command cannot be executed because a NAME/TOKEN
write error occurred. The XP7 mainframe agent will now
stop.
return-code
Return code set by the NAME/TOKEN registration routine
(IEANTCR)
name
Name registered in the NAME/TOKEN service
A NAME/TOKEN
WRITE ERROR OC-
CURRED,RC=return-
code,NAME=name
YKY021I CON
The specified prefix is being used by another program.
Check the initialization parameters.
THE SPECIFIED PREFIX
IS BEING USED BY AN-
OTHER PROGRAM
YKY022I CON
The XP7 mainframe agent was terminated.AGENT ENDEDYKY051I CON
The XP7 mainframe agent termination processing has begun.
AGENT IN SCHEDULED
SHUTDOWN
YKY052I CON
Messages80